Condition-monitoring review · Free browser tool

Ultrasound Bearing dB Trend Tool

See what changed from a bearing’s ultrasound baseline. Check whether readings are comparable, review a local route log, and keep threshold crossings separate from a diagnosis.

Make the assumptions visible.

Free · no sign-in · no upload · no email required. Inputs and results stay in this page. Links and exports are shared only when you choose.

Interactive controls require JavaScript. The worked example, method, limitations and sources below remain readable.

Compare like with like before interpreting a change.

Enter instrument-reported dB readings from the same marked point, instrument/scale, sensor, mounting, frequency and comparable operating conditions. Review sensitivity/gain handling, speed, load, lubrication history and sound quality. A matching frequency and sensor label in a file do not verify all those conditions.

The tool subtracts baseline from current reading. It does not assume the display is calibrated dBµV, convert between instruments or infer a physical amplitude from an unspecified dB reference. The legacy CSV header dbuv is accepted as an instrument-level column name only.

Review levels are prompts to investigate.

The editable starting levels are +8, +12, +16 and +35 dB relative to baseline. Public UE Systems material uses similar values, but stage labels differ between its article and sensor guide. They are context-dependent vendor guidance, not universal diagnostic limits. This tool reports which review levels are crossed; it does not assign a failure stage, prescribe grease or establish safe operation. Below the first level does not prove good condition. A drop below the separate −8 dB review level also calls for checking the reading and context.

A route log needs a traceable baseline.

Rows are grouped by asset and point together. Mark one baseline per point. If none is marked, the earliest row is used and flagged for review; that choice does not establish that the bearing was healthy. More than one marked baseline stops the import. Earlier rows and changed frequency/sensor readings are excluded from comparisons and regression. If any reading on the latest date has changed settings, the current review band is withheld. An earlier comparable result is labeled with its date.

Duplicate dates are retained. The latest-date summary uses the highest recorded level; regression gives each distinct date equal weight using the arithmetic mean of comparable instrument dB readings for that date. This mean is a statistical summary of displayed levels, not an energy average. Repeated measurements can hide important peaks; inspect the raw rows and sound evidence.

A fitted line is not a remaining-life model.

Least-squares regression uses instrument level versus elapsed days, with at least three distinct comparable dates. Slope is reported per 30 days, not a calendar month. R² describes that line’s fit to the historical daily means; it is not a probability of failure or confidence level.

The optional threshold-line extrapolation is off by default. It requires verified comparability, at least four distinct dates, positive slope, R² ≥ 0.60 and a crossing after the latest recorded reading within a 365-day display horizon. These are display checks, not validated forecasting criteria. The selected level must not already be reached. A date derived from old history may already be in the past today. No forecast from today, failure date or remaining useful life is calculated.

Worked example: separate change, fit and interpretation.

Example (synthetic): The sample point starts at 28 dB on January 5, 2026, with readings 29, 30, 33 and 38 at 28-day intervals. Its latest change is +10 dB, crossing the first starting review level. That is a prompt to review the evidence, not a lubrication instruction.

The fitted line has slope 2.57143 dB per 30 days, intercept 26.8 dB at day zero and R² ≈ 0.88344. If deliberately enabled, its +16 dB threshold line (44 dB) crosses at day 200.6667: July 24, 2026 at 16:00 UTC. This is an extrapolation from the recorded sample, not a failure forecast. Another sample point changes sensor and frequency, so its latest comparison is withheld.

Questions before you use the result

Does +8 dB mean I should add grease?

No. It crosses one starting review level. Confirm sound quality, baseline suitability, instrument settings, operating conditions and the approved lubrication procedure before choosing an action. This tool does not decide grease quantity or interval.

Why can’t I compare readings from different instruments?

A displayed dB value depends on the instrument reference and measurement chain. Identical numbers or matching sensor labels do not establish interchangeability. Use a validated site procedure.

What happens when the latest sensor or frequency changes?

The latest comparison band and current slope summary are withheld. Earlier comparable readings can be reviewed as dated history; they are not presented as the current condition.

Does my route file leave the browser?

No. Parsing and analysis run in a local browser worker, with no file-upload endpoint, tool analytics or account save. The page and worker use connect-src none. No local or session storage is used. Clear all local data or reload to remove the working dataset.

What can I import?

UTF-8 CSV, semicolon-delimited or tab-delimited text with the documented column names, up to 5 MiB, 20,000 readings and 1,000 asset/point pairs. Required: asset_id, point_id, date, level_db, frequency_khz and sensor. Optional: is_baseline, location and notes. Invalid rows stop the import; none are silently dropped.

What does a copied link contain?

Mode, review levels and projection display settings; quick mode also includes its baseline/current numbers. It never includes route rows, point IDs, notes or file names, and never prechecks comparability for the recipient. Opening a numeric link exposes those values in the URL and normal hosting logs.

Method and sources

Method references checked November 21, 2026. Original Apex explanations, diagrams, examples and implementation; no copyrighted standard tables or figures are reproduced.

This tool provides an engineering estimate, not a substitute for OEM data or a qualified engineer. Results depend on the inputs you provide and on published approximations that may not fit your equipment. Verify before acting.

Turn the result into a practical next step.

Apex can help review the evidence, scope and maintenance decision. Calculator inputs and imported rows are not transferred to the inquiry.

Discuss an Ultrasound Monitoring Route

Start a free engineering brief · Browse all free tools