Inspection planning · Free browser tool
P–F Interval and Inspection Frequency Calculator
Turn an estimated warning window and time to act into a conditional inspection plan. See the assumptions before choosing a real task interval.
Make the assumptions visible.
Free · no sign-in · no upload · no email required. Inputs and results stay in this page. Links and exports are shared only when you choose.
Your results
Reserve time to act before choosing an interval.
The P–F interval runs from a detectable potential-failure condition to the defined functional failure. Supply a credible value for this failure mode, detection method, operating state and detection criterion. A technology name alone does not establish a warning interval.
Net warning window = P–F interval − response lead time. The rule-of-thumb interval is net window ÷ n. The default n = 2 is a planning heuristic, not a quoted standards requirement. Practical intervals round down to 1, 7, 14, 28, 91, 182 or 365 days. Sub-daily results show no listed whole-day interval.
The probability option assumes independent inspections with an unchanged probability p of detecting a condition already present. Required k = ceiling[ln(1 − target) ÷ ln(1 − p)]. Detection probability across k inspections = 1 − (1 − p)k. Real detectability changes with degradation and inspections can share the same blind spot; this simple model does not verify p.
Nominal opportunity counts divide the net window by the planning interval. Actual opportunities depend on inspection timing relative to onset, access, missed routes, signal quality and response delays. The diagram is an original illustration, not a measured condition trend or a remaining-life forecast.
Days, weeks and months are converted to days; months use 30.4375 days. Entered operating hours are divided by your supplied operating hours per day. Make sure the warning and response durations refer to a consistent time basis. Regulatory, OEM, insurer and site requirements still govern the actual task.
Worked example: preserve response time.
Example (synthetic): A supplied 42-day P–F interval and a 14-day response lead time leave a 28-day net window. With divisor 2, the raw interval is 14 days, and the practical interval is also 14 days. This does not establish that a real failure mode gives 42 days of warning.
If response time is 12 days but the warning interval is only 10 days, the entered action cannot fit. More frequent inspection alone cannot recover the missing response time.
Questions before you use the result
Why use half the warning window?
Dividing by two provides nominal opportunities to detect the condition. It is a heuristic that still needs credible detection performance, timing margin and a technically applicable task.
Does continuous monitoring fix an infeasible window?
It can reduce sampling delay but cannot create response time when the lead time already exceeds the warning interval. Review earlier detection, shorter response or another maintenance strategy.
Can I share a failure-mode or asset name?
Copied links omit free-text labels. Use generic descriptions in the worksheet and review any exported file before sharing it.
Is the calculated interval an approved inspection schedule?
No. The calculation is a planning aid. A qualified review must establish applicability, consequences, evidence, requirements and the actual task interval.
Method and sources
Method references checked November 21, 2026. Original Apex explanations, diagrams, examples and implementation; no copyrighted standard tables or figures are reproduced.
- NASA: Reliability-Centered Maintenance Guide, September 2008 — Condition-monitoring context, detection uncertainty and adjustment of monitoring intervals. The calculator’s algebra and examples are original Apex work.
- Apex: RCM service scope — Failure-mode and consequence review before selecting a maintenance strategy.
This tool provides an engineering estimate, not a substitute for OEM data or a qualified engineer. Results depend on the inputs you provide and on published approximations that may not fit your equipment. Verify before acting.
Turn the result into a practical next step.
Apex can help review the evidence, scope and maintenance decision. Calculator inputs and imported rows are not transferred to the inquiry.