Example: Root Cause Analysis of Repeat Gearbox Failures
Follow a fictional gearbox investigation from evidence and competing hypotheses to proposed checks.
Root cause failure analysis is a disciplined way to explain a specific failure and to recommend actions that can be checked. It is not a workshop to confirm a cause someone already chose in the hallway. The sequence below is a working order, not a branded method with a trademark.
When the hardware itself has to be examined, can sit inside the same investigation. For a facilitated RCFA, see . If you are still choosing which failure to investigate, start with bad actors.
Original fictional exercise. A pump bearing runs hotter after a lubrication task. “Too much grease” is a possible explanation, not a demonstrated root cause. Preserve the as-found condition and compare these alternatives before choosing corrective work.
Keep each explanation marked open, supported or rejected, with its evidence and counter-evidence. If records are missing, state what cannot yet be concluded. Any inspection or test needs an agreed safe method and appropriate isolation; this example is not a live-equipment test instruction.
If evidence eventually supports a lubrication cause, an action might revise the controlled quantity/method and verify the revised task was carried out. That checks implementation. A separate effectiveness check compares bearing condition and recurrence under comparable duty for an agreed observation period. Completion of training or a work order alone does not prove the failure mechanism is controlled. Assign an owner, due date, measure and review point before closing the action.
See the fictional gearbox investigation report for an example evidence register and action plan. Its outcomes are illustrative, not achieved customer results.
Public source reviewed November 14, 2026: U.S. Department of Energy, Contractor Investigation, Causal Analysis, and Corrective Actions, EGS 05-01. This archived nuclear-enforcement guidance supports evidence, cause/action linkage and effectiveness verification; it is not presented as a current general-industry requirement. The worked example and wording above are original Apex explanations.